Continuous-Service Duplex Filter for Process Liquids
Two switchable chambers allow filtration to continue while one basket or element is isolated, drained and cleaned.
1. Filtration continues during element service
You can divert the flow between chambers without shutting down the whole process.
2. Valve arrangement coordinated with the piping
Check that changeover valves, handles, and flow direction are easy to operate.
3. Basket or element selected for the contaminant
Choose the internal filter type based on particle size, solids load, and how often cleaning is needed.
4. Pressure loss monitored across the duty cycle
Use clean and changeout differential-pressure limits to help with sizing and maintenance.
Duplex Filter Description
A duplex liquid filter lets one side keep working while the other is shut off for cleaning or replacing the filter basket. Before opening the isolated side, make sure it is depressurized, drained, and at zero pressure. Various cover designs can make it easier to access the basket and give enough space for safe removal. You can add a differential pressure indicator to help track contaminant buildup and know when to switch sides. Depending on the fluid and how the system operates, you can choose reusable baskets, fine filter elements, magnetic inserts, or corrosion protection.
Duplex Filter Technical Data Sheet
| Duplex Filter Technical Data Sheet | ||
| Parameter | Tinsins Typical Manufacturing Range | Unit / Configuration |
| Operating flow | 1–1,000 | m³/h |
| Basket filtration rating | 25–5,000 | μm |
| Cartridge filtration rating | 5–100 | μm |
| Clean-filter pressure drop | Calculated for each element and fluid | kPa |
| Connection size | DN25–DN400 | Flanged |
| Design pressure | 0.6–4.0 typical | MPa |
| Design temperature | -20 to 180 | °C |
| Typical alarm ΔP | 0.05–0.10 | MPa |
| Chamber capacity | 100% design flow per chamber | Duty philosophy |
| Element collapse differential | Supplier-defined | MPa |
| Housing material | Carbon steel, 304/304L, 316/316L | Project selection |
| Seal material | NBR, EPDM, FKM or PTFE | Project option |
| Changeover method | Manual or actuated | Valve / linked valves |
| Equalization and venting | Included as required | Piping option |
| Drain and dirty-side isolation | Per chamber | Standard requirement |
| Changeover leakage class | Project-defined | Seat leakage requirement |
| Instrumentation | Upstream/downstream pressure or differential-pressure transmitter | Project option |
| Inspection and test | NDE, hydrostatic and seat/leak test | ITP |
| Applicable design basis | GB/T 150 or project-specified code | Custom fabrication |
| Required RFQ data | Fluid, flow, viscosity, solids load, particle size and target rating | Customer input |
Configure a Duplex Filter System
Share the full flow, viscosity, filtration target and preferred changeover method. We will review chamber capacity, valve arrangement and safe isolation details.
Duplex Filter Applications
- Duplex Filter for Steel Mill Cooling and Rolling Fluids
This filter removes scale, metal particles, and debris from cooling water, rolling oils, and other fluids used in steel and metal production. With its duplex design, you can clean one basket while the other side keeps the production line running. - Twin Basket Filter for Pulp and Paper Process Water
This filter captures fibers, bark particles, and suspended solids from mill water, coating liquids, and other process streams. Continuous filtration protects spray nozzles, pumps, and heat-transfer equipment from blockages and abrasive wear. - Continuous Duplex Strainer for Paint and Resin Production
This filter removes agglomerates, dried material, and foreign particles from paints, inks, coatings, and resins during mixing or transfer. The basket mesh, seal material, and housing are chosen based on viscosity, solvent compatibility, and allowed pressure drop. - Duplex Filtration System for Industrial Wastewater Reuse
This system removes coarse suspended solids from collected process water before it is reused or sent for further treatment. One side can keep running while the other is depressurized, drained, and cleaned following the approved procedure.
Duplex Filter Changeover and Maintenance Video
What Happens During Changeover?
The operating procedure should prevent both chambers from being closed at once and avoid sending a pressure surge downstream. Equalization and venting may be necessary before a cleaned chamber returns to service.
One Chamber Must Carry the Full Flow
Sizing the pair for shared flow defeats the purpose of online maintenance. Each chamber and its element should be checked at the maximum operating duty expected during changeover.